CO2 and air quality detector - Thermomètre/Hygromètre - Technoline WL 1030
CO₂ meter WL1030 technoline monitor for air quality
Description
The quality control of the air (CO2 compensator) is a test method that can be trusted by the association of consummaters and recommendations.
Capteur de gaz infrarouge non dispersif (NDIR) de haute qualité avec une plage de mesure de CO2 at least 5000 ppm. Guidelines for ventilation based on the concentration of CO2 in the air. Plus, the equipment is suitable for the humidity of the air and the temperature.
Ideal for the public baths such as hairdressing salons, schools, gymnasiums, museums, sport clubs, etc. Besides, it is a good idea to measure the quality of the air in your home.
More or less the world is the basis for the ventilation and the quality of the air that is important. To monitor the quality of the air, it is important to ensure that the air quality is sufficient. The quality of the work done by the quality of the posters on the equipment. The plus is to receive a consultation of the ventilation car according to the color of the changeover.
(Les chiffres parlent d'eux-mêmes, le texte sur l'appareil est en allemand)
Before first use:
Les valeurs sont posters dans les 2,5 minutes. Ensuite, the equipment with the calibration (automatic) pendant 24 hours for the details of the measurements. The process of preparing the equipment for the placement of the equipment is an example for measuring the quality of the air in the air itself. Thanks for the careful processing of the quality of the air technology of the Technoline and the guarantee of precision.
Would you like to know more about CO2?
Pourquoi behind un compteur de CO2 ?
The level of exposure of CO2 is due to the concentration and performance of the person, which is also a factor in the propagation of the virus. It is recommended that ventilation be regulated and opportune to improve the interior climate and maintain safety!
The people who inspire the oxygen and expirent of CO2. Si beaucoup de personnes sont assizes ensemble dans un espace clos, il ya de moins en moins d'oxygène et de plus en plus de CO2 dans l'air. The quantity of CO2 of the particles per million (mètre cube) or PPM in terms of the propreté of the air.
The CO2 detection method requires the ventilation of one piece and the PPM poster based on the quantity of CO2 present in the air.
Since the PPM varies over time, the air changes and the risk of transmission of germs increases. At 800 ppm, the virus sonet plus propagation facilities. The plus, if the CO2 value is superior to 1500 ppm, it is important to increase the level of pollution. With PPM atteint 2000 ppm, the person is responsible for the medium of the body, the concentration of the body, the attention, the acceleration of the cardiac rhythm and the natural processes.
The ventilation is a piece of windows with PPM at a normal inferior level of 800 ppm.
Niveaux et directives de CO2
Niveaux et directives de CO2
Reference levels for CO2 references:
400~600ppm
Exterior air level (normal).
600~1.000ppm
Typical level for the pieces occupied by the open circulation of the air.
1.000~1.500ppm
Commencez à venter la pièce.
1.500~2.000ppm
Niveau associate à des plaintes de somnolence et de mauvaise qualité de l'air.
Ventilation recommended!
2.000~5.000ppm
Niveau associé aux de tête, à la somnolence et à un stagnant, vicié et confiné. A mauvaise concentration, a strong attention, an acceleration of cardiac rhythm and the continuous monitoring. Ventilation is recommended!
> 5.000 ppm
The exposure is caused by a grave hypoxia, which is the cause of the permanent permanent brain cells, the coma and the death. This is why immediate ventilation is necessary!
CO2 properties
FEATURES
- Capteur de quality de l'air pour la surveillance de la quality de l'air dans les espaces clos
- Capteur de gaz infrarouge non dispersif (NDIR) with a level of CO₂ measured at 5000 ppm, based on the ventilation principles of the CO₂ in the air
- Poster of the interior temperature in °C or °F
- Poster of the interior humidité
- Storage of the valeurs MIN/MAX of the dernières 24 hours with the automatic defilement function
- Capteur de qualité de l'air pour la surveillance de la qualité de l'air
- Alarm adjustable for the value of measuring the CO₂ with optional alarm signal
- Adjustable alarms for the superior and inferior temperature and humidity limits
- Calibration function for CO₂, temperature and humidity
- Mémoire ROM intégrée pour l'enregistrement des réglages, retroéclairage with levels of luminosity réglables.
Technical Data
TECHNICAL DATA
Dimensions: x 94 145 50 mm x
Alimentation : Alimentation électrique (incluse)
Temperature range: 0 °C - 50 °C / 32 °F to 122 °F
Temperature resolution: 0,1 °C
Plage d'humidité: 20% - 95% HR
Humidity solution: 1%
Function temperature: 0 °C to 50 °C / 32 °F to 122 °F <95 %, without condensation
CO2
Measurement area: 400 - 5000
PPM Solution: 1 PPM
Precision: +/- 5% + 50 PPM
Pre-chauffage time: 1 minute
Poster beach
CO2 : 400 (≤ 400PPM)HI (≥ 5000PPM)
Température : LO (≤ 0 °C / 32 °F).HI (≥ 50 °C / 122 °F).
Humidity: 20% (≤ 20%)95% (≥ 95%)
Standard parameters
Alarm CO2 : faible -400, élevé 2000HR%
Alarm: Faible 35%, Élevé 70%.
Sound CO2 alarm: Deactivated
Temperature: °C
Poster luminosity level: high
Manuel
Le manuel néerlandais se trouve here